![]() Up to 4 x 4 modules may be connected to one Processing Unit II. Operate the module with CMC-TC: No additional power pack is needed the module is supplied with power via the CMC-TC system. Usable functions: Current display, circuit display, automatic selective activation Up to two or three modules may be operated in one PSM rail (1200/2000 mm) with one power pack. Operate the module without CMC-TC: For operation of the module, power pack 7201210 and a connection cable (see page 70) are needed. The module is twice the length of a standard PSM module, so that a maximum of 2 modules may be inserted into a 1200 mm long PSM rail, and a maximum of 3 modules into a 2000 mm long PSM rail. Furthermore, a current indicator, circuit display, and thermal overload protection are integrated into the module. Each of the 8 outlets are individually switchable (via the CMCTC system). The active plug-in module for the busbar system PSM has 8 current outlets with IEC320 C13 slots. The vertical support rail allows the slots to be used flexibly across the entire enclosure height, and configured in a redundant manner via separate power infeed to the individual modulesĬontrol Power System Module (PSM) 8 Outlet Support rail may be integrated into the vertical frame section of the Power System Rack without additional equipment.Over voltage protection may be integrated into the supply line.All plug-in modules are equipped with an integral miniature circuit-breaker, so that only the affected module is deactivated in the event of a short circuit.Modules may be retrofitted while the system is operational.Each plug-in module picks off a phase on the support rail, either from infeed A or from the second infeed B, depending on the direction of module.The redundant circuit is completely separate from the 3 phases of the support rail.A redundant three-phase infeed with 3 x 20 A may also be added.3-Phase construction with a maximum current of 3 x 20 A.This is easily achieved, even by non-electricians, thanks to the shock hazard protected plug & play system. may be inserted into the support rail in any combination. The various modules, grounding pins, IEC320, etc. This can even be done while the system is operational because the support section is shock hazard protected. The various modules to supply the active components may be snap-fitted into the support rail. The modular system facilitates the basic configuration of the racks, thanks to a vertical support rail with 3-phase infeed. The new “intelligent power distribution system” from 42U significantly reduces cabling and assembly work, leading to a reduction in costs. The ever-growing power requirements of modern IT infrastructures demand advanced solutions for power distribution inside the racks, leading to the requirement for additional sockets. 80AĤ2U Power Distribution Module Package Contents: Module 482.6 mm (19″), 3UĤ2U’s Vision is to inspire corporate responsibility in energy efficiency and be a leader in providing technology and vendor agnostic information, suggestions, and solutions for making data centers more energy efficient. Including master switch, optional RC circuit breaker.482.6 mm (19″) Power Distribution Module mechanically locked in the rack.**The Power Distribution Module is required. The 42U PDU kit includes the enclosure frame with doors (without tubular door frame), rear panel, side panels and roof plate, leveling feet including base/plinth adapter, grounding of all enclosure panels, busbars shock-hazard-protected, main switch integrated. The gland plates, punched sections with mounting flanges and mounting angles are a zinc-plated and passivated. The doors, roof, and base/plinth are a dipcoat primed in RAL 7035 and powder coated in RAL 7035. Surface Finish: Enclosure frames are a dipcoat primed in RAL 7035.Depending on the standards of the local power supply company Note: Observe the standards of the local power supply companies. ![]() A maximum of 32 racks may be connected to the sub-distributor.PDM may be retrofitted while operational.Height 1.20 m (48″) for 4 PDMs and 2 m (79″) height for 8 PDMs.Power Distribution Rack to accommodate a maximum of 8 PDMs
0 Comments
Leave a Reply. |